Àüüº¸±â
 

´©¼³Àü·ù°è(VÃøÁ¤) CM-03 [AC0.01mA~60A,30¥Õ]
¿ø»êÁö :´ë¸¸
Á¦Á¶»ç :ÇÁ·Î¹Ù[PROVA]
ºê·£µå :ÇÁ·Î¹Ù[PROVA] [ºê·£µå¹Ù·Î°¡±â]
»ç¿ë±Ô°Ý :AC0.01mA~60A,30¥Õ
´©¼³Àü·ù°è(VÃøÁ¤) CM-03 [AC0.01mA~60A,30¥Õ]
340,000¿ø
¤ý°ø±Þ°¡¾×(VATº°µµ) :
¤ýÆǸŰ¡¾×(VATÆ÷ÇÔ) :


¢Ã Accurate AC digital clamp meter for leakage current measurement
¢Ã 10§Ë high resolution on 40mA range
¢Ã Shield transformer jaws to minimize the effect of external stray magnetic field
¢Ã Large jaw with 30mm diameter
¢Ã Five Ranges (40mA, 400mA, 4A, 40A, 60A) for all application
¢Ã A filter circuit is designed to eliminate the effect of high frequency noise
and harmonics for AC current measurement
¢Ã Large 3-3/4 Degits LCD (4000 Counts)
¢Ã Fast bargraph display
¢Ã Continuity and frequency measurements
¢Ã Max/Min, Data Hold functions and Relative Measurement
¢Ã 600 V Overload Protection for Ohm Measurement

ELECTRICAL SPECIFICATIONS : (23¡É¡¾5¡É)

¡á AC Current :

Range

Resolution

Accuracy

50/60Hz

Wide(40-1KHz)

40mA

10¥ìA

¡¾1.0% rdg ¡¾3 dgts

¡¾2.0% rdg ¡¾5 dgts

400mA

100¥ìA

¡¾1.0% rdg ¡¾3 dgts

¡¾2.0% rdg ¡¾5 dgts

4A

1mA

¡¾1.0% rdg ¡¾3 dgts

¡¾2.0% rdg ¡¾5 dgts

40A

10mA

¡¾1.0% rdg ¡¾3 dgts

¡¾2.0% rdg ¡¾5 dgts

60A(0-50A)

100mA

¡¾1.5% rdg ¡¾3 dgts

¡¾3.0% rdg ¡¾5 dgts

60A(50-60A)1

100mA

¡¾3.0% rdg ¡¾5 dgts

¡¾3.5% rdg ¡¾5 dgts

1 Though the meter can display up to 400A, it is not calibrated beyond 60A

¡á AC Voltage : (Input Impedance : 10M§Ù)

Range

Resolution

Accuracy

Overload Protection

50/60Hz

40 - 1KHz

400V

0.1V

¡¾1.5%¡¾2dgts

¡¾2.0%¡¾4dgts

AC 800V

¡á Resistance(§Ù) and Continuity : (Open Voltage 0.4V)

Range

Resolution

Accuracy

Beeping

Overload Protection

40-400§Ù

0.1§Ù

¡¾1.0%¡¾2dgts

<38.0§Ù

AC 600V

GENERAL SPECIFICATIONS :

- Conductor Size : 30mm max. (approx.)
- BatteryType : two 1.5V SUM-3AA
- Display : 3-3/4 LCD with 40 seg. bargraph
- Range Selection : manual
- Overload Indication : left most digit blinks
- Power Consumption : 10mA (approx)
- Sampling Time : 2 times/sec. (display)
20 times/sec. (bargraph)
- Operating Temperature : -10¡É to 50¡É
- Operating Humidity : less than 85% relative
- Storage Temperature : -20¡É to 60¡É
- Storage Humidity : less than 75% relative
- Dimension : 210mm (L) x 62.0mm (W) x 35.6mm (H)
- Weight : 200g (battery Included)
- Accessories : Carrying bag, Users manual, 1.5V battery, Test Leads


* ¹è¼Û °ü·Ã ¾È³»
±âº»¹è¼Û·á´Â 3,000¿ø ÀÔ´Ï´Ù. (µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù)
ÁÖ¹®°Ç´ç  100,000¿ø ÀÌ»ó °áÁ¦½Ã ¹«·á·Î ¹è¼ÛÀ» Çص帳´Ï´Ù. (´Ü, Äü¼­ºñ½ºÀÌ¿ë ÂøºÒ, Ç×°ø·á ÂøºÒ)
°áÁ¦°¡ È®ÀÎµÈ ÀÌÈÄ ¹è¼ÛÀÌ °¡´ÉÇϸç, ¿µ¾÷ÀÏ ±âÁØÀ¸·Î °áÁ¦ÀÏ+1ÀÏ À̳» ¹è¼ÛÃâ°í¸¦ ¿øÄ¢À¸·Î ÇÏ°í ÀÖ½À´Ï´Ù.
»óÇ°ÀÇ Àç°í»óȲ¿¡ µû¶ó ¹ß¼ÛÀÌ Áö¿¬µÇ°Å³ª, ±¸¸Å°¡ ºÒ°¡´ÉÇØÁö´Â °æ¿ì ´ç»ç¿¡¼­ °í°´´Ô²² ¹Ýµå½Ã ¸ÕÀú ¿¬¶ôµå¸®°Ú½À´Ï´Ù.
* ±³È¯ ¹× ¹ÝÇ° ¾È³»